BCQHW - SYNTHOL COLOR SOLV REDUCER, 8005
- MSDS: BCQHW
- Manufacturer: MARTIN SENOUR AUTOMOTIVE SALES
- Product Name: SYNTHOL COLOR SOLV REDUCER, 8005
- National Stock Number: 8010-00N008458
Product Identification
Product ID:SYNTHOL COLOR SOLV REDUCER, 8005
MSDS Date:02/08/1988
FSC:8010
NIIN:00N008458
MSDS Number: BCQHW
Responsible Party
COUNTRYSIDE, IL 60525
US
Emergency Phone: 216-566-2917
Info Phone: 216-566-2902
Cage: MART3
Contractor
Telephone: 216-566-2902
Cage: 16772
Ingredients
6.58 LBS, 789
RTECS: 9999999VO
Fraction By Weight: SEE ING
CONCENTRATING & INHALING CONTENTS CAN BE HARMFUL OR
RTECS: 9999999ZZ
PROCS. KEEP CNTNRS CLSD WHEN NOT IN USE.
RTECS: 9999999ZZ
SOLVENT NAPHTHA (PETROLEUM), LIGHT ALIPHATIC; (LIGHT
CAS: 64742-89-8
Fraction By Weight: 45%
OSHA PEL 100 PPM
22
CAS: 108-88-3
RTECS: XS5250000
Fraction By Weight: 55%
OSHA PEL 200 PPM/150 STEL
ACGIH TLV: 50 PPM; 9293
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:NOTE:TOLUENE (108-88-3) APPEARS ON
NAVY LIST OF OCCUP CHEMICAL REPRO HAZS. CONSULT WITH APPROP HLTH
PROFS CONCERNING LATEST HAZ LIST INFO & SAFE HNDLG & EXPOS RECOMS .
ACUTE:IRRIT OF EYES, SKIN & RESP SYS. MAY CAUSE NERV SYS
DEPRESS.EXTREME OVEREXP MAY RSLT IN UNCON & POSS DEATH. HDCH, DIZZ,
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:NAUS & LOSS OF COORD ARE INDICATIONS
OF EXCESS EXPOS TO VAPS/SPRAY MISTS. REDNESS & ITCH/BURNING
SENSATION MAY INDICATE EYE/EXCESS SKIN EXPOS. CHRONIC:PRLNG OVEREXP
TO SOLV INGS MAY CAUSE ADV ERSE EFTS TO LIVER, URINARY, BLOOD
FORMING SYS & CVS. REPORTS HAVE ASSOC RPTD & PRLNG OVEREXP TO SOLVS
W/PERM (SUPDAT)
Medical Cond Aggravated by Exposure:NONE GENERALLY RECOGNIZED.
First Aid
First Aid:INHAL:REMOVE FROM EXPOS. RESTORE BRTHG. KEEP WARM & QUIET.
SKIN:WASH AFFECTED AREA THORO W/SOAP & WATER. REMOVE CONTAM CLTHG &
LAUNDER BEFORE RE-USE. EYES:FLUSH W/LG AMTS OF WATER FOR AT LST 15
MINS. GET MED ATTN. INGEST:NEVER GIVE ANYTHING BY MOUTH TO UNCON
PERS. DO NOT INDUCE VOMIT. GIVE SEVERAL GLASSES OF WATER. SEEK MED
ATTN.
Fire Fighting
Flash Point Method:TCC
Flash Point:25.0F,-3.9C
Lower Limits:1.0
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, FOAM.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP
. WATER SPRAY MAY BE INEFT. IF WATER IS USED, FOG NOZZS ARE PREF.
WATER MAY BE USED TO COOL CLSD (SUPDAT)
Unusual Fire/Explosion Hazard:KEEP CNTNRS TIGHTLY CLSD. ISOLATE FROM
HEAT, ELEC EQUIP, SPKS & OPEN FLAME. CLSD CNTNRS MAY EXPLODE WHEN
EXPOSED TO EXTREME HEAT. APPLICATION TO HOT (SUPDAT)
Accidental Release
Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION.VENTILATE &
REMOVE W/INERT ABSORBENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:DO NOT TAKE INTERNALLY. KEEP OUT OF
REACH OF CHILDREN. USE ONLY W/ADEQ VENT. AVOID EYE, SKIN CONT.
AVOID BRTHG VAP/SPRAY MIST.
Other Precautions:CONTENTS FLAMM. KEEP AWAY FROM HEAT, SPK, OPEN FLAME.
DURING USE & UNTIL ALL VAPS GONE:KEEP VENTED, DO NOT SMOKE, EXTING
ALL IGNIT SOURCES, TURN OFF STOVE, ELEC TOOLS, APPLIANCES. CONSULT
NFPA CODE. U SE APPRVD BONDING & GROUNDING (ING 5)
Exposure Controls
Respiratory Protection:IF PERSONAL EXPOS CANNOT BE CONTROLLED BELOW
APPLIC LIMITS BY VENT, WEAR A PROPERLY FITTED NIOSH/MSHA APPROVED
ORGANIC/VAPOR PARTICULATE RESP FOR PROTECTION AGAINST MATERIALS IN
INGS SECTION.
Ventilation:LOC EXHST PREF; MECH ACCEPT. IF EXPOS TO INGS IS BELOW
APPLIC LIMS REFER TO OSHA 1910.94, 1910.107, 1910.108.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:WASH HANDS AFTER USE.
Supplemental Safety and Health
FIRE FIGHT PROC:CNTNRS TO PVNT PRESS BUILD-UP & POSS AUTOIGNIT/EXPLO
WHEN EXPOSED TO EXTREME HEAT. EXPLO HAZ:SURFS REQS SPECIAL PRECS.
DURING EMER CNDTNS OVEREXP TO DECOMP PRODS MAY CAUSE HLTH HAZ. SY
MPS MAY NOT BE IMMED APPARENT. OBTAIN MED ATTN. EFTS OF
OVEREXP:BRAIN & NERV SYS DMG. INTENT MISUSE BY DELIB (ING 4)
Chemical Properties
HCC:F3
Boiling Pt:B.P. Text:>200F,>93C
Vapor Pres:SEE INGS
Vapor Density:HVR/AIR
Spec Gravity:0.788
Evaporation Rate & Reference:SLOWER THAN ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:100
Stability
Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:CARBON MONOXIDE, CARBON DIOXIDE.
Disposal
Waste Disposal Methods:MAY BE HAZ UNDER RCRA 40CFR261. WASTE MUST BE
TESTED FOR IGNITABILITY TO DETERM APPLIC EPA HAZ WASTE #. INCIN IN
APPRVD FACILITY. DO NOT INCIN CLSD CNTNR. DISP I/A/W FED, STATE &
LOC REGS REGARDING PO LLUTION.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.